Zander Medical
Octax Laser Shot

"We believe that quality is never an accident; it is always the result of high intention, sincere effort, intelligent direction and skillful execution; it represents the wise choice of many alternatives.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Contact Our
Sales Staff

 

 

 

 


 

OCTAX LASER SHOT- FDA 510(k)-K062524-Registered for Clinical Use

 
  • Highest optical and mechanical quality
  • Complete with imaging software and database Octax Laser Shot
  • Highest optical and mechanical quality
  • Outstanding scientific background:
    • 1st birth after laser assisted hatching (1.48 µm)
    • 1st birth after laser assisted blastomere biopsy and PGD
    • 1st birth after laser assisted polar body biopsy
    • 1st birth after laser assisted immobilization of spermatozoa
    • 1st pregnancy after laser assisted zona drilling for ICSI
    • 1st ongoing pregnancy after laser assisted removal of necrotic blastomeres from cryopreserved embryos

OCTAX Laser ShotT System for ART

OCTAX Laser Shot™ Technical Specifications

  • Laser: Infrared Diode Laser
  • Wavelength: 1.48 µm
  • Power in focus: 90 - 130 mW +/- 5% (depending on microscope model)
  • Irradiation time: 0.1 - 50.0 ms, in 0.1 ms steps
  • Video display: with OCTAX EyeWare™ on Computer monitor
  • Status indication: LED on OCTAX Laser Shot™ module, user interface on computer (OCTAX EyeWare™)
  • Release of laser irradiation: via mouse or external foot trigger, repetitive single shot, acoustic feedback
  • Laser irradiation indication: LED on Laser module + user interface on computer (OCTAX EyeWare™)
  • Drilling precision: < 1 µm
  • Drilling reproducibility: < 1 µm
  • Drilling range with one shot: ˜ 1 µm to ˜ 50 µm (depending on Zona pellucida characteristics)
  • Drilling range with multiple shots: arbitrary size
  • Beam position stability: < 5 µm per month
  • External connectors (Laser module): connection to computer via USB cable, and power supply
  • Foot trigger: 3 x 9 x 10 cm3, cable 5 mm ø, length 3.00 m
  • Main switch: Key lock at rear of Laser module
  • Supply voltage: 100 - 240 V AC, 50 or 60 Hz, 15 VA
  • Mechanical dimensions (OCTAX Laser Shot™ module): 9.0 x 9.0 x 13 cm3
Technical specifications are subject to change without notice. Documentation created with OCTAX EyeWareT

     
Octax Eyeware  
 
 

 