LN2 Low Level Alarms from Gordinier
for Liquid Nitrogen Containers

Model 610 Battery Operated - Item # GE 610/40-610

GordinierThe model 610 liquid nitrogen low level alarm, is a small self-contained unit with features you would expect to find only in larger costly alarms. This unit comes complete with a probe, three nickel cadmium batteries, and a power adapter for battery charging.

FEATURES:

  • Built-in battery charger
  • Continuous alarm (5 days on full battery charge)
  • Universal 9 volt AC wall transformer/Option 220 volt
  • Open or shorted probe protection
  • Push to Test button (battery and alarm can both be tested at the same time)
  • Easy Installation
  • Compact size (3 1/4" x 5 1/2" x 1 3/4") Nitrogen container
  • Complete with mounting bracket to fit on the unit handle
  • Remote Relay Output
  • Progressive Audible Horn
  • Work Mute Button
  • Open Probe Alarm
  • Low Level Alarm
  • Press to Test Remote Relay (15 seconds)
  • Press to Test Alarm (5 seconds)
  • Flashing Alarm LED (normal no flashing)
  • Universal 9 VAC Wall Transformer

Model 610 is a battery operated liquid nitrogen (LN2) Low Level Alarm, providing up to 5 days of alarm on one (1) charge. This handy unit is also equipped with a built-in battery charger, a bracket designed to protect the unit during fill and provide easy access to the front plate.

 
 

Model 626 Low nitrogen alarmModel 626 LN² LOW LEVEL ALARM
Small Dewar Lid Size

FEATURES:

  • Low Level Alarm
  • Work Mute Button
  • Progressive Audible Horn
  • Press to Test Remote Relay (5 seconds)
  • Flashing Alarm LED (normal no flashing)
  • Universal 9 volt AC Wall Transformer (117 volt /OPTION 220 volt)
  • Open Probe Alarm
  • Shorted Probe Alarm
  • Remote Alarm Output

This unique controller has been designed to provide a complete working alarm system. This alarm provides protection during the time the probe is unplugged, or removed from the Dewar When the probe is removed from the dewar during a work function, simply press the work button. This will keep the alarm in a momentary standby mode (approximately 10 minutes). If the probe is not returned after 10 minutes, the alarm will slowly return to its full audible horn and activate the remote relay.

The Progressive Audible Horn allows the operator to remove the probe from the dewar without the unit going into an audible and a remote relay alarm. Pressing the Work/Mute button will lower the horn sound (which has been factory set). After 10 minutes the horn will gradually increase to maximum volume. This will alert the operator to place the probe back into the dewar, or press the Work/Mute button again.

 

 

 
 